Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — CONTROL VALVE

10 Structure, function and maintenance standard SEN00286-01 Function q When the lift valve is at “float“, the cylinder port and drain port are connected to put the circuit in a no-load condition. q When the lift valve is in the “float“ condition, the pump passage and cylinder ports (A3) and (B3) are separated so that the other control valves can be operated. Operation q When the work equipment control lever is at the “float” position, if pressure (PA3) becomes 3.4 MPa {35 kg/cm 2 } or more, lift spool (1) is moved to the maximum stroke position. q In this condition, ports (A3), (B3) and LS pas- sage (O) are all connected to the drain circuit, so there is no load on the lift cylinder.

q If the cylinder is driven by the weight of the blade, the oil entering from port (A3) flows to ports (A), (B), (B') and (A'), while the rest of the pressurized oil flows through ports (C) and (D), and is drained. q When this happens, the oil flow is throttled by the area of opening between ports (A) and (B) of spool (1), and the cylinder speed is con- trolled. q The pump circuit chamber (E) and ports (A3) and (B3) are separated, and pump pressure (P) is formed, so it is possible to carry out com- pound operations with other control valves. D65EX, PX, WX-15E0 23