Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — CONTROL VALVE

10 Structure, function and maintenance standard SEN00286-01 q d = P – P2 q d PO = Differential pressure between ports (H) and (K) q Pressure P2 = LSO + d PO Function q When steering valve (1) and work equipment valve (2) are relieved at the same time, the pump pressure is separated by pressure com- pensation valve (3) in the work equipment valve, and the port pressure is maintained at a constant value. Operation q If HSS motor (6) reaches the stall condition, the load pressure increases and LS relief valve (4) for the steering valve is actuated, so the system is cut off. q For details, see topic “1. Steering valve“.

q When this happens, the pump pressure is maintained at 38.2 MPa {390 kg/cm 2 }, and this is sent to chamber (G) of the work equipment valve. q When work equipment valve (2) is operated and the load on the work equipment valve is greater, work equipment LS relief valve (5) is actuated, and drain oil flow (Q1) flows to LS circuit (O). q As a result, a differential pressure is generated on the left and right sides of pressure compen- sation valve (3) by LS throttle (M) of spool (2), and it moves the full stroke to the right. q When this happens, the opening between chambers (D) and (E) is throttled to the mini- mum size (pump pressure separated).

q Oil flow (Q1) is determined by pump pressure (P) and the total pressure loss d (P – LSO) of ports (C), (D), (E), (F), (G), (I), (J) and (K). q Furthermore, pressure (P2) (the pressure in chamber (H)) becomes the total (LSO + d PO) of the circuit pressure loss of ports (H), (I), (J) and (K), and the set pressure of work equip- ment LS relief valve (5). D65EX, PX, WX-15E0 29