Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — CONTROL VALVE

10 Structure, function and maintenance standard SEN00286-01 Function When pump swash plate does not reach maxi- mum angle q The steering valve is equipped with steering priority valve (3), so if the steering valve and the downstream work equipment valve are operated at the same time, priority is given to the flow of oil to the steering valve, and the rest of the oil discharged from the pump goes to the work equipment valve. q When the maximum oil flow from the pump is greater than the sum of the flow demanded by the steering valve and work equipment valve, an amount of oil that matches the opening of steering spool (1) flows to the steering valve.

q An amount of oil decided by the pump pres- sure, the load pressure and the area of the spool opening flows to the work equipment valve. Operation q When steering spool (1) is operated by pilot pressure (P1) and the oil flows, a differential pressure is created between chambers (C) and (D). q When the maximum flow of oil from the pump is smaller than the sum of the oil flow demanded by the steering valve and work equipment valve.

When pump swash plate is at maximum angle q Steering priority valve (3) is controlled by this differential pressure, and at the same time, the pump swash plate angle is controlled at ( d PLS) = 2.0 MPa {20 kg/cm 2 }, and the flow of oil to the steering valve is fixed. 1) When steering valve load Z work equipment valve load. q For details, see topic “1. Steering valve” of “Control of oil flow.” q In this condition, if downstream work equip- ment lift spool (2) is operated, the pump pres- sure momentarily drops. q An amount of oil that matches the opening of steering spool (1) flows to the steering valve, and the remaining oil flows to work equipment valve.

q At this point, the differential pressure between chambers (C) and (D) becomes smaller, and steering priority valve (3) is moved to the left by the pressure in chamber (E) in the direction to throttle the opening to the work equipment valve. 2) When steering valve load > work equipment valve load. q Pump pressure (P) is determined by the steer- ing valve load, but in this condition, if the downstream work equipment valve where the load is smaller is operated, the difference in pressure will cause the oil to try to flow to the work equipment valve, so the pump pressure will drop.

q At the same time, ( d PLS) becomes smaller, so the pump swash plate angle moves in the max- imum direction to supply an oil flow to make up the amount that the pressures drop. q When this happens, steering priority valve (3) increases the size of the opening to the steer- ing system, while at the same time reducing the size of the opening to the work equipment in order to ensure the flow of oil to the steering system. q In this condition, the flow of oil is divided in pro- portion to the difference in pressure between differential pressure (P) – (P1) and differential pressure (P) – (P2). q The bigger (P1) – (P2) is, the smaller the flow of oil to the steering system becomes.

D65EX, PX, WX-15E0 31