SEN00287-01 10 Structure, function and maintenance standard 2. Output voltage characteristics q The control unit is installed to the left control stand and the control lever is installed directly onto it. q The operating angle [stroke] of the control levers sensed with potentiometers and signal voltages are output to the transmission, steer- ing controller. q A potentiometer is installed in each of longitu- dinal direction and lateral direction. Each potentiometer outputs 2 signal voltages which are opposite to each other as shown in the fig- ure at right. 14 D65EX, PX, WX-15E0