Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — HANDLING ELECTRIC EQUIPMENT AND HYDRAULIC COMPONENT

00 Index and foreword SEN00056-01 3) Disconnections in wiring If the wiring is held and the connectors are pulled apart, or components are lifted with a crane with the wiring still connected, or a heavy object hits the wiring, the crimping of the connector may separate, or the sol- dering may be damaged, or the wiring may be broken. 4) High-pressure water entering connector The connector is designed to make it diffi- cult for water to enter (drip-proof struc- ture), but if high-pressure water is sprayed directly on the connector, water may enter the connector, depending on the direction of the water jet. Accordingly, take care not splash water over the connector.

The con- nector is designed to prevent water from entering, but at the same time, if water does enter, it is difficult for it to be drained. Therefore, if water should get into the con- nector, the pins will be short-circuited by the water, so if any water gets in, immedi- ately dry the connector or take other appropriate action before passing electric- ity through it. 5) Oil or dirt stuck to connector If oil or grease are stuck to the connector and an oil film is formed on the mating sur- face between the male and female pins, the oil will not let the electricity pass, so there will be defective contact.

If there is oil or grease stuck to the connector, wipe it off with a dry cloth or blow it dry with com- pressed air and spray it with a contact restorer. a When wiping the mating portion of the connector, be careful not to use excessive force or deform the pins. a If there is oil or water in the com- pressed air, the contacts will become even dirtier, so remove the oil and water from the compressed air com- pletely before cleaning with com- pressed air. D65EX, PX, WX-15E0 11