Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — HANDLING ELECTRIC EQUIPMENT AND HYDRAULIC COMPONENT

00 Index and foreword SEN00056-01 2) Connecting connectors 1] Check the connector visually. Check that there is no oil, dirt, or water stuck to the connector pins (mating portion). Check that there is no deformation, defective contact, corrosion, or dam- age to the connector pins. Check that there is no damage or breakage to the outside of the con- nector. a If there is any oil, water, or dirt stuck to the connector, wipe it off with a dry cloth. If any water has got inside the connector, warm the inside of the wiring with a dryer, but be careful not to make it too hot as this will cause short circuits. a If there is any damage or break- age, replace the connector.

2] Fix the connector securely. Align the position of the connector correctly, and then insert it securely. For connectors with lock stopper, push in the connector until the stop- per clicks into position. 3] Correct any protrusion of the boot and any misalignment of the wiring har- ness. For connectors fitted with boots, cor- rect any protrusion of the boot. In addition, if the wiring harness is mis- aligned, or the clamp is out of posi- tion, adjust it to its correct position. a If the connector cannot be cor- rected easily, remove the clamp and adjust the position. q If the connector clamp has been removed, be sure to return it to its original position.

Check also that there are no loose clamps. 3) Connecting DT connectors Since the DT 8-pin and 12-pin heavy duty wire connectors have 2 latches respec- tively, push them in until they click 2 times. 1. Male connector 2. Female connector q Normal locking state (Horizontal): a, b, d q Incomplete locking state (Diagonal): c D65EX, PX, WX-15E0 13