Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — COOLING SYSTEM CONTROL SYSTEM

10 Structure, function and maintenance standard SEN00290-01 Outline Selection of fan rotation mode q The transmission and steering controller moni- tors the coolant, power train oil, and hydraulic oil temperatures and controls the fan speed according to those temperatures. q While the starting switch is in the “on“ position and the engine is stopped, one of the following fan rotation modes can be selected with the fan rotation selector switch. Fan rotation mode includes; 1) Forward rotation mode 2) Cleaning mode According to the selected mode, the transmis- sion and steering controller operates the reverse solenoid valve of the cooling fan motor to change the rotation direction of the fan.

Function Fan speed control q The transmission and steering controller con- trols the discharge of the cooling fan pump to set the fan speed properly according to the information from the coolant, power train oil, and hydraulic oil temperature sensors. q The transmission and steering controller selects the maximum target fan speed obtained from the coolant, power train oil, and hydraulic oil temperatures and outputs it as the pump control signal to the cooling fan pump. 1) Forward rotation mode In this mode, the reverse solenoid valve does not operate and the fan rotates for- ward. The fan speed varies with the tem- perature sensor signal. This mode is selected normally.

q The cooling fan pump changes its swash plate angle to control its oil discharge for the cooling fan motor. 2) Cleaning mode In this mode, the fan rotates in reverse at high speed to blow off dirt from the radia- tor fins, regardless of the temperature sensor signals. If this mode is used peri- odically, the cleaning interval of the radia- tor fins can be expanded. While in the “Cleaning mode“, the machine does not move for the radiator protection even if the PCCS lever is shifted to “forward“ or “reverse“ posi- tion.The starting switch needs to be turned from “off“ to “on“ to restart the machine under the “forward rotation mode“.

Interlock for changing rotation mode q If the rotation direction of the fan is changed while the fan is rotating, the fan drive circuit is broken. To prevent this, the fan rotation selec- tor switch signal is ignored while the engine is running. In this case, the fan operation pilot lamp on the monitor panel flashes for 3 sec- onds. D65EX, PX, WX-15E0 13