SEN00585-00 30 Testing and adjusting Testing fuel return and leak amount 1 2) Connect testing tool J1 on supply pump side, and insert the tip into measuring cyl- inder J4 . 3) Connect block tool J1 to fuel return con- nector side, and block fuel leak. 4) Run the engine at low idle and test the return rate from the supply pump. a If the return rate from the supply pump is in the following range, it is normal. a Testing tools for leakage from pressure limiter and return rate from injector Low idle 300 cc/30 sec. Cranking 200 cc/30 sec. k When the engine cannot run, you may test it by cranking the engine with the starting motor.
To protect the starting motor, do not continu- ously crank the engine 30 seconds or more. 1. Testing supply pump return rate 1) Remove supply pump bolt (2), and discon- nect return tube (1). 5) After finishing testing, remove the testing tools and return the removed parts. 3 Joint bolt: 24 ± 4 Nm {2.4 ± 0.4 kgm} 26 D65EX, PX, WX-15E0 Symbol Part No. Part name J 1 Part No. being established Tool to check supply pump 2 Part No. being established Pressure limiter testing tool 3 Part No. being established Tool to check injector 4 Commercial item Measuring cylinder