Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS)

30 Testing and adjusting SEN00586-00 D65EX, PX, WX-15E0 19 Action code Failure code Failure area Trouble symptom Alarm Buzzer Cont roller History classification CALL E03 CA451 Common rail pressure sensor too high Excessively high voltage detected q ENG Electric system CALL E03 CA452 Common rail pressure sensor too low Excessively low voltage detected q ENG Electric system CALL E03 CA488 Charge temperature too high torque derated Exceeded upper control limit of temperature q ENG Electric system CALL E03 CA553 Common rail pressure too high (1) Excessively high pressure detected q ENG Electric system E02 CA559 Supply pump no pressure (1) No pressure feeding detected q ENG Electric system CALL E03 CA689 Abnormal engine NE speed sensor Abnormality in signal q ENG Electric system CALL E03 CA731 Abnormal engine Bkup speed sensor phase Abnormal phase q ENG Electric system CALL E04 CA757 Loss of all data of engine con- troller Loss of all data q ENG Electric system CALL E03 CA778 Abnormal engine Bkup speed sensor Abnormal Bkup signal q ENG Electric system CALL E03 CA1633 Abnormal KOMNET Abnormal communication q ENG Electric system CALL E03 CA2185 Decelerator pedal sensor power source too high Excessively high voltage detected q ENG Electric system CALL E03 CA2186 Decelerator pedal sensor power source too low Excessively low voltage detected q ENG Electric system CALL E03 CA2249 Supply pump no pressure (2) No pressure feeding detected q ENG Electric system CALL E03 CA2265 Disconnection in electric lift pump Disconnection q ENG Electric system CALL E03 CA2266 Short circuit in electric lift pump Short circuit q ENG Electric system CALL E03 CA2311 Abnormal IMV solenoid Abnormal resistance q ENG Electric system E01 CA2555 Disconnection in air intake heater relay Disconnection ENG Electric system E01 CA2556 Short circuit in air intake heater relay Short circuit ENG Electric system — D110KA Battery relay Short circuit S/T Electric system — D110KB Battery relay Disconnection S/T Electric system E02 D130KA Neutral safety relay Disconnection q S/T Electric system E02 D130KB Neutral safety relay Short circuit q S/T Electric system E01 D161KA Backup alarm relay Disconnection S/T Electric system E01 D161KB Backup alarm relay Short circuit S/T Electric system CALL E03 DAFRKR Monitor panel CAN communica- tion Defective communication q MON Electric system E01 DAQ0KT (DB30KT) Steering and transmission con- troller Abnormality in controller S/T Electric system CALL E04 DAQ1KK (DB31KK) Main power source of steering and transmission controller Power supply voltage drop, input q S/T Electric system CALL E04 DAQ2KK (DB32KK) Steering and transmission con- troller load power source Power supply voltage drop, input q S/T Electric system CALL E03 DAQ5KK (DB35KK) 5V power source of steering and transmission controller sensor Power supply voltage drop, input q S/T Electric system