Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS)

30 Testing and adjusting SEN00586-00 Detailed information on bit display codes 31520 : Input state of transmission-related fill switch 1: Forward clutch fill switch: ON 2: Reverse clutch fill switch: ON 3: 1st clutch fill switch: ON 4: 2nd clutch fill switch: ON 5: 3rd clutch fill switch: ON 6: (Unused) 7: (Unused) 8: (Unused) Display of bit information: a The display position of the bit information in the “Real-time monitoring mode (Display of only 1 item)” is different from that in the “Dual display monitoring mode (Simultaneous display of 2 items)”. a The bit information is displayed by [ _ ] for OFF and [o] for ON in the places from 1 to 8.

a The state of each item shown in this section is the condition for turning on the bit. 40905 : Transmission-related controller input signal 1 1: Shift up switch: OFF 2: Shift up switch: ON 3: Shift down switch: OFF 4: Shift down switch: ON 5: (Unused) 6: (Unused) 7: (Unused) 8: (Unused) 18800 : Water level signal of fuel filter 1: Water level in fuel filter: When detecting 2: (Unused) 3: (Unused) 4: (Unused) 5: (Unused) 6: (Unused) 7: (Unused) 8: (Unused) D65EX, PX, WX-15E0 39