Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — INSPECTION PROCEDURE OF DIODE

30 Testing and adjusting SEN00587-00 Inspection procedure of diode 1 2. When using analog tester 1) Switch to resistance range. 2) Check the deflection of needle while con- necting as follows. i) Set red (+) test lead to diode anode (P) side and black (–) test lead to cathode (N) side. ii) Set red (+) test lead to diode cathode (N) side and black (–) test lead to anode (P) side. 3) Based on the deflection of needle, judge the quality of diode. a The direction of continuity of diode is marked on the surface of the diode. q Needle does not deflect with connec- tion i) but deflects with connection ii): Normal.

(however deflection range (resistance value) varies depending on the type of tester and measuring range. 1. When using digital tester 1) Switch to diode range and check dis- played value. a Voltage of internal battery is dis- played by normal tester. 2) Set red (+) test lead to diode anode (P) side and black (–) test lead to cathode (N) side. Check displayed value. 3) Judge quality of diode from displayed value. q Needle deflects with both connection i) and ii): Defective (internal short cir- cuit) q Needle does not deflect with either connection i) or ii): Defective (internal disconnection) q Displayed value does not change: No continuity (defect) q Displayed value changes:

Continue (normal) (note) Note: In the case of silicon diode, the value between 460 – 600 mV is dis- played. q Displayed value becomes 0 or near 0 : Short-circuiting of diode internal part (defect) D65EX, PX, WX-15E0 9