30 Testing and adjusting SEN00587-00 Pm-clinic check sheet Always fill in the record when repairing, adjusting, or replacing main parts. D65EX, PX, WX-15E0 15 Serial number T D65EX-15 # T D65PX-15 # T D65WX-15 # Work order Date Service meter Serviceman / / h Check item Measurement conditions Unit Standard value for new machine Service limit value Measurement results Pass Fail Steering Steering load sensing pressure Engine at full throttle MPa {kg/cm2} 32.8 – 36.8 {335 – 375} Min. 30.9 {Min. 315} Steering relief actuating pressure 34.8 – 38.8 {355 – 395} Min. 32.8 {Min. 335} Brake Brake actuating pressure Engine at full throttle 2.75 – 2.94 {28 – 30} Min. 2.55 {Min.
26.0} Brake performance Apply brake and run engine at full throttle with transmission gear in F2. Machine must not move Check item Measurement conditions Unit Standard value for new machine Service limit value Measurement results Pass Fail Hydraulic system Work equipment load sensing pressure Engine at full throttle MPa {kg/cm2} 18.6 – 22.6 {190 – 230} Min. 17.6 {Min. 180} HSS and work equipment pump Ripper lift relief Engine at low idle Min. 19.6 {Min. 200} Min. 19.6 {Min. 200} Blade tilt relief Min. 19.6 {Min. 200} Min. 19.6 {Min. 200} Ripper lift relief Engine at full throttle 20.6 – 24.6 {210 – 250} Min. 19.6 {Min. 200} Blade tilt relief 20.6 – 24.6 {210 – 250} Min. 19.6 {Min.
200} PPC valve output pressure Blade tilt relief 3.53 – 4.41 {36 – 45} 3.53 – 4.41 {36 – 45} Check item Measurement conditions Unit Standard value for new machine Service limit value Measurement results Pass Fail Work equipment speed Blade RAISE Engine at full throttle Second EX: 2.1 – 2.8 WX: 2.1 – 2.8 PX: 1.9 – 2.6 Max. 3.1 Max. 3.1 Max. 2.9 Single tilt (left o right) Engine at full throttle 2.0 – 2.6 Max. 2.8 Ripper RAISE Engine at full throttle 1.2 – 1.6 Max. 1.9 Check item Measurement conditions Unit Standard value for new machine Service limit value Measurement results Pass Fail Hydraulic drift Hydraulic oil temperature Engine stopped °C 45 – 55 — Blade lift cylinder mm/ 15 min. Max.
100 Max. 100 Blade tilt cylinder Max. 200 Max. 200 Check item Measurement conditions Unit Standard value for new machine Service limit value Measurement results Pass Fail Visual inspection of final drive drain plug Engine stopped — There must be no excessive metal particles Date Service meter Repair record Date Service meter Repair record