SEN00589-00 40 Troubleshooting Contents of troubleshooting table 1 a The following information is summarized in the troubleshooting table and the related electrical circuit diagram. Before carrying out troubleshooting, understand that information fully.
12 D65EX, PX, WX-15E0 Action code Failure code Failure symptom Trouble that appears in the machine Display of panel Display of panel Failure content State where the monitor panel or controller detects the trouble Controller's action Action to be taken to protect the system and equipment when the monitor panel or controller detects a trouble Symptoms that appears on machine Problem that appears as an abnormality in the main unit by the action taken by the monitor panel or controller (above) General information Information related to troubles occurred or troubleshooting Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Cause by which a trouble is assumed to be detected (The order number indicates a serial number, not a priority sequence.) • • Standard value when normal required to judge the possible cause • Remarks required to judge whether the cause is right or not • Disconnection in wiring The connector contact is defective or the wiring harness is disconnected.
• Defective grounding A harness not connected to GND (ground) circuit comes into contact with the GND (ground) circuit. • Hot short defect A harness not connected to the electric power supply (24 V) circuit comes into contact with the electric power supply (24 V) circuit. • Short circuit A harness abnormally comes into contact with a harness of separate circuit. (1) Method of indicating connector numbers and handling T- adapter For troubleshooting, insert or connect the T- adapter as described below unless especially specified. • When “male” or “female” is not indicated for a connector number, disconnect the connector, and insert the T- adapter in both the male and female.
• When “male”or “female” is indicated for a connector num- ber, disconnect the connector, and insert the T-adapter in only either the male or female. (2) Pin number description sequence and tester lead handling For troubleshooting, connect the plus (+) and minus (–) leads of the tester as described below unless especially specified. • Connect the plus (+) lead to a pin number or harness indi- cated in the front. • Connect the minus (–) lead to a pin number or harness indicated in the rear. 2 3 4