Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [15SBL1] REVERSE CLUTCH: FILL SIGNAL IS ON WHEN COMMAND CURRENT IS OFF

SEN00589-00 40 Troubleshooting Failure code [15SBL1] Reverse clutch: Fill signal is ON when command current is OFF 1 20 D65EX, PX, WX-15E0 Action code Failure code Failure symptom Reverse clutch: Fill signal is ON when command current is OFF (Steering and transmission controller system) CALL E03 15SBL1 Failure content • The fill switch signal does not become off when the output of the transmission reverse clutch sole- noid circuit has stopped. Controller's action • Flashes warning lamp and turns on alarm buzzer. • Determines to apply neutral (N) to forward operation. • Limits operation of engine and transmission.

Symptoms that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to R1. General information • The input state (ON/OFF) from the reverse clutch fill switch can be checked in monitoring mode. (Code 31520: Transmission fill switch input state) • Duplication of failure code: Engine start + travel neutral Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective reverse clutch fill switch (internal short circuit) aPrepare with starting switch OFF, then start the engine for trou- bleshooting.

RSW (male) PCCS lever Resistance Between (1) – chassis ground N Min. 1 Mz R (Reverse) Max. 1 z 2 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF, then start troubleshooting with starting switch OFF. Between ground and wiring harness between ST2 (female) (25) – RSW (female) (1) Resis- tance Min. 1 Mz 3 Defective steering and transmission controller aPrepare with starting switch OFF, then start the engine for trou- bleshooting. ST2 PCCS lever Voltage Between (25) – chassis ground N 5 – 11 V R (Reverse) Max.

1 V 4 Defective hydraulic pressure system When no fault is detected in the electric system, the hydraulic pres- sure system is assumed to be abnormal. Carry out the related trou- bleshooting (H-mode).