Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [15SBLH] REVERSE CLUTCH: FILL SIGNAL IS OFF WHEN COMMAND CURRENT IS ON

SEN00589-00 40 Troubleshooting Failure code [15SBLH] Reverse clutch: Fill signal is OFF when command current is ON 1 22 D65EX, PX, WX-15E0 Action code Failure code Failure symptom Reverse clutch: Fill signal is OFF when command current is ON (Steering and transmission controller system) CALL E03 15SBLH Failure content • The fill switch signal does not become ON when the output of the transmission reverse clutch sole- noid circuit is ON. Controller's action • Flashes warning lamp and turns on alarm buzzer. • Decides that engine speed is neutral (N) at reverse operation. • Limits operation of engine and transmission.

Symptoms that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1. General information • The input state (ON/OFF) from the reverse clutch fill switch can be checked in monitoring mode. (Code 31520: Transmission fill switch input state) • Duplication of failure code: Engine start + reverse travel Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective reverse clutch fill switch (internal short circuit) aPrepare with starting switch OFF, then start the engine for trou- bleshooting.

RSW (male) PCCS lever Resistance Between (1) – chassis ground N Min. 1 Mz R (Reverse) Max. 1 z 2 Disconnection in wiring har- ness (Disconnection or poor con- nector contact) aPrepare with starting switch OFF, then start troubleshooting with starting switch OFF. Wiring harness between ST2 (female) (25) – RSW (female) (1) Resis- tance Max. 1 z 3 Defective steering and transmission controller aPrepare with starting switch OFF, then start the engine for trou- bleshooting. ST2 PCCS lever Voltage Between (25) – chassis ground N 5 – 11 V R (Reverse) Max.

1 V 4 Defective hydraulic pressure system When no fault is detected in the electric system, the hydraulic pres- sure system is assumed to be abnormal. Carry out the related trou- bleshooting (H-mode).