Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [CA123] CHARGE PRSSURE SENSOR TOO LOW: EXCESSIVELY LOW VOLTAGE DETECTED

SEN00589-00 40 Troubleshooting Failure code [CA123] Charge pressure sensor too low: Excessively low voltage detected 1 40 D65EX, PX, WX-15E0 Action code Failure code Failure symptom Charge pressure sensor too low: Excessively low voltage detected (Engine controller system) CALL E03 CA123 Failure content • Excessively low voltage is detected at pressure signal circuit of boost pressure and temperature sen- sor. Controller's action • Operates with a fixed charge pressure. Symptoms that appears on machine • Engine output is reduced. General information • The signal voltage of boost pressure and temperature sensor on boost pressure side can be checked in monitoring function. (Code:

36501 Boost pressure sensor voltage) • Duplication of failure code: turn ON the starting switch. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective sensor power source 2 system If failure code [CA187] is displayed at the same time, carry out trou- bleshooting for that first. 2 Defective boost pressure and temperature sensor [pressure signal circuit] aPrepare with starting switch OFF, then start troubleshooting with starting switch ON.

C4 Voltage Between (2) – (4) Power source 4.75 – 5.25 V Since voltage is measured with the harness connected, further diag- nose the harness and the controller if the voltage is not normal, and then make judgment after it is determined that there is no other defective cause. 3 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF, then start troubleshooting with starting switch OFF. Between ground and wiring harness between CE01 (female) (44) – C4 (female) (1) Resis- tance Min. 100 kz 4 Harness short (Harness internal short) aPrepare with starting switch OFF, then start troubleshooting with starting switch OFF.

Wiring harness between CE01(female) (44) – C4 (female) (1) and wiring harness among CE01(female) (47) – S11 – C4 (female) (4) Resis- tance Min. 100 kz 5 Defective wiring harness connector The connections among boost pressure and temperature sensor – engine harness – engine controller are suspected to be defective. Visually check it. • Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded. • Moisture in connector, entry of dirt or sand, etc., and insufficient insulation 6 Defective engine controller aPrepare with starting switch OFF, then start troubleshooting with starting switch ON. CE01 Voltage Between (37) – (47) Power source 4.75 – 5.25 V