Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [CA227] SENSOR POWER SOURCE 2 TOO HIGH: EXCESSIVELY HIGH VOLTAGE DETECTED

SEN00589-00 40 Troubleshooting Failure code [CA227] Sensor power source 2 too high: Excessively high voltage detected 1 62 D65EX, PX, WX-15E0 Action code Failure code Failure symptom Sensor power source 2 too high: Excessively high voltage detected (Engine controller system) CALL E03 CA227 Failure content • Excessively high voltage has been detected in sensor power source 2 circuit Controller's action • Operates with a fixed boost pressure. • Operates with fixed charge temperature. • Runs by limiting output. Symptoms that appears on machine • Engine output is reduced. General information • Duplication of failure code: turn ON the starting switch.

Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective wiring harness connector The connections among each sensor – engine harness – engine controller are suspected to be defective. • Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded. • Moisture in connector, entry of dirt or sand, etc., and insufficient insulation 2 Defective engine controller Engine controller is possibly defective if no problem is found in cause 1. (Internal failure which cannot be diagnosed)