SEN00589-00 40 Troubleshooting Failure code [CA272] IMV/PCV1 disconnection: Disconnection 1 68 D65EX, PX, WX-15E0 Action code Failure code Failure symptom IMV/PCV1 disconnection: Disconnection (Engine controller system) CALL E03 CA272 Failure content • Disconnection is detected at drive circuit of supply pump actuator. Controller's action • No particular action Symptoms that appears on machine • Engine runs, but it does not stabilize. • Fuel pressure of common rail increases above commanded value. General information • Duplication of failure code: turn ON the starting switch.
Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective supply pump actu- ator aPrepare with starting switch OFF, then start troubleshooting with starting switch OFF. C17 (male) Resistance Between (1) – (2) Max. 5 z 2 Disconnection in wiring har- ness (Disconnection or poor con- nector contact) aPrepare with starting switch OFF, then start troubleshooting with starting switch OFF. Wiring harness between CE01 (female) (2) – C17 (female) (1) Resis- tance Max. 10 z Wiring harness between CE01 (female) (32) – C17 (female) (2) Resis- tance Max.
10 z 3 Hot short of harness (a contact with 24 V circuit) aPrepare with starting switch OFF, then start troubleshooting with starting switch ON. Between ground and wiring harness between CE01 (female) (2) – C17 (female) (1) Voltage Max. 3 V 4 Harness short (Harness internal short) aPrepare with starting switch OFF, then start troubleshooting with starting switch OFF. Between CE01 (female) (2) – CE01 (female) all pins (With all connectors in the harness disconnected) Resis- tance Min. 100 kz 5 Defective wiring harness connector The connections among inlet metering valve – engine harness – engine controller are suspected to be defective. Visually check it.
• Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded. • Moisture in connector, entry of dirt or sand, etc., and insufficient insulation 6 Defect in other locations than engine controller aPrepare with starting switch OFF, then start troubleshooting with starting switch OFF. CE01 (female) Resistance Between (2) – (32) Max. 5 z 7 Defective engine controller Engine controller is possibly defective if no problem is found in causes 1 – 6. (Internal failure which cannot be diagnosed)