Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [CA281] ABNORMAL SUPPLY PUMP PRESSURE BALANCE: ABNORMAL PRESSURE FEED OF FUEL

SEN00589-00 40 Troubleshooting Failure code [CA281] Abnormal supply pump pressure balance: Abnormal pressure feed of fuel 1 70 D65EX, PX, WX-15E0 Action code Failure code Failure symptom Abnormal supply pump pressure balance: Abnormal pressure feed of fuel (Engine controller system) CALL E03 CA281 Failure content • Due to the abnormality in supply pump mechanical system, response of fuel pressure feed is not appropriate. Controller's action • No particular action Symptoms that appears on machine • Engine does not start. Or it starts, but it does not stabilize. • The pressure of high-pressure fuel is different in front side and rear side of supply pump.

General information • Duplication of failure code: start the engine. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Residual air in the fuel circuit Refer to “Bleeding air from fuel circuit” in Testing and adjusting, and bleed air from the fuel circuit. 2 Defective wiring harness connector Problem is possibly at the connections between common rail pres- sure sensor – engine harness – engine controller, so inspect them directly. • Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded.

• Moisture in connector, entry of dirt or sand, etc., and insufficient insulation 3 Defective engine controller Engine controller is possibly defective if no problem is found in causes 1 – 2. (Internal failure which cannot be diagnosed)