Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [CA322] INJECTOR NO.1 SYSTEM DISCONNECTION OR SHORT CIRCUIT: DISCONNECTION, SHORT CIRCUIT

SEN00590-00 40 Troubleshooting Troubleshooting by failure code (Display of code), Part 2 1 Failure code [CA322] Injector No. 1 system disconnection or short circuit: disconnection, short circuit 1 4 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Injector No. 1 system disconnection or short circuit: disconnection, short circuit (Engine controller system) CALL E03 CA322 Failure content • A disconnection or short circuit has been detected in No. 1 injector drive circuit. Controller's action • No particular action Symptoms that appears on machine • Poor combustions or hunting occurs. • Engine output is reduced. General information • Duplication of failure code: start the engine.

Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective engine controller If the following failure codes are displayed at the same time, engine controller is internally defective: ([CA322] [CA324] [CA331]) 2 Defective No. 1 injector aPrepare with starting switch OFF and diagnose with starting switch still OFF. C9 (male) Resistance Between (3) – (4) Max. 2 z Between (3) – chassis ground Min. 100 kz 3 Disconnection in wiring harness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between CE01 (female) (45) – C9 (3) – No.

1 injector (1) Resis- tance Max. 2 z Wiring harness between CE01 (female) (53) – C9 (4) – No. 1 injector (2) Resis- tance Max. 2 z 4 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harness between CE01 (female) (45) – C9 (3) – No. 1 injector (1) Resis- tance Min. 100 kz 5 Harness short (Harness internal short) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between CE01 (female) (45) – CE01 (female) all pins (All connectors in the harness disconnected) Resis- tance Min.

100 kz Between CE01 (female) (53) – CE01 (female) all pins (All connectors in the harness disconnected) Resis- tance Min. 100 kz 6 Defective wiring harness connector Since the problem is possibly at the connections between No. 1 injector – engine harness – engine controller, check for a defective connection. • Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded. • Moisture in connector, entry of dirt or sand, etc., and insufficient insulation