SEN00590-00 40 Troubleshooting Failure code [CA323] Injector No. 5 system disconnection or short circuit: disconnection, short circuit 1 6 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Injector No. 5 system disconnection or short circuit: disconnection, short circuit (Engine controller system) CALL E03 CA323 Failure content • A disconnection or short circuit has been detected in No. 5 injector drive circuit Controller's action • No particular action Symptoms that appears on machine • Poor combustions or hunting occurs. • Engine output is reduced. General information • Duplication of failure code: start the engine.
Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective engine controller If the following failure codes are displayed at the same time, engine controller is internally defective: ([CA323] [CA325] [CA332]) 2 Defective No. 5 injector aPrepare with starting switch OFF and diagnose with starting switch still OFF. C11 (male) Resistance Between (3) – (4) Max. 2 z Between (3) – chassis ground Min. 100 kz 3 Disconnection in wiring har- ness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between CE01 (female) (46) – C11 (3) – No.
5 injector (1) Resis- tance Max. 2 z Wiring harness between CE01 (female) (60) – C11 (4) – No. 5 injector (2) Resis- tance Max. 2 z 4 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harness between CE01 (female) (46) – C11 (3) – No. 5 injector (1) Resis- tance Min. 100 kz 5 Harness short (Harness internal short) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between CE01 (female) (46) – CE01 (female) all pins (All connectors in the harness disconnected) Resis- tance Min.
100 kz Between CE01 (female) (60) – CE01 (female) all pins (All connectors in the harness disconnected) Resis- tance Min. 100 kz 6 Defective wiring harness connector Since the problem is possibly at the connections between No. 5 injector – engine harness – engine controller, check for a defective connection. • Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded. • Moisture in connector, entry of dirt or sand, etc., and insufficient insulation