Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [CA352] SENSOR POWER SOURCE 1 TOO LOW: EXCESSIVELY LOW VOLTAGE DETECTED

SEN00590-00 40 Troubleshooting Failure code [CA352] Sensor power source 1 too low: Excessively low voltage detected 1 18 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Sensor power source 1 too low: Excessively low voltage detected (Engine controller system) CALL E03 CA352 Failure content • Excessively low voltage has been detected in sensor power source 1 circuit Controller's action • Operates with a fixed atmospheric pressure. Symptoms that appears on machine • Startability of engine deteriorates. • Engine output is reduced. General information • Duplication of failure code: turn ON the starting switch.

Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective sensor or wiring harness aPrepare with starting switch OFF and diagnose with starting switch ON. Disconnect the devices on the right one at a time and try to duplicate the problem. If the failure code changes from flashing to continu- ously illuminating, that device or harness is defective. Atmospheric pres- sure sensor C29 Engine harness CE01 2 Defective wiring harness connector Since the connections among atmospheric pressure sensor – engine harness – engine controller are suspected to be defective, check for a defective connection.

• Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded. • Moisture in connector, entry of dirt or sand, etc., and insufficient insulation 3 Defective engine controller Engine controller is possibly defective if no problem is found in causes 1 – 2. (Since this is an internal defect, it cannot be diag- nosed.)