Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [CA386] SENSOR POWER SOURCE 1 TOO HIGH: EXCESSIVELY HIGH VOLTAGE DETECTED

SEN00590-00 40 Troubleshooting Failure code [CA386] Sensor power source 1 too high: Excessively high voltage detected 1 Circuit diagram related to sensor power supply 1 20 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Sensor power source 1 too high: excessively high voltage detected (Engine controller system) CALL E03 CA386 Failure content • Excessively high voltage has been detected in sensor power source 1 circuit Controller's • action Operates with a fixed atmospheric pressure. Symptoms that • appears • on machine Startability of engine deteriorates. Engine output is reduced. General • information Duplication of failure code: turn ON the starting switch.

Possible causes and the 1 standard values when normal 2 Cause Standard value when normal and remarks for troubleshooting Defective wiring harness connector Since the connections among atmospheric pressure sensor – engine harness – engine controller are suspected to be defective, check for a defective connection. • Connector is loose, lock is broken, seal is broken Pin is corroded, bent, broken, pushed in, expanded. Moisture in connector, entry of dirt or sand, etc., and insufficient insulation Defective engine controller Engine controller is possibly defective if no problem is found in cause 1. (Since this is an internal defect, it cannot be diagnosed.)