SEN00590-00 40 Troubleshooting Failure code [CA429] Water detection sensor too low: Excessively low voltage detected 1 24 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Water detection sensor too low: Excessively low voltage detected (Engine controller system) E01 CA429 Failure content • Excessively low voltage has occurred in the fuel water detection sensor signal circuit Controller's action • No particular action Symptoms that appears on machine • Water separator monitor does not display normally. General information • The signal status of the fuel water detection sensor can be checked with the monitoring function. (Code:
18800 Fuel filter water level signal) • Duplication of failure code: turn ON the starting switch. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective fuel water detec- tion sensor aPrepare with starting switch OFF and diagnose with starting switch still OFF. WIF (female) Resistance Between (1) – (2) Max. 10 z Between (1) – chassis ground Min. 100 kz 2 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harness between CE01 (female) (14) – WIF (male) (1) Resis- tance Min.
100 kz 3 Harness short (Harness internal short) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between CE01 (female) (14) – CE01 (female) all pins (All connectors in the harness disconnected) Resis- tance Min. 100 kz 4 Defective wiring harness connector Problem is possibly at the connections between fuel water detection sensor – engine harness – engine controller, so inspect them directly. • Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded.
• Moisture in connector, entry of dirt or sand, etc., and insufficient insulation 5 Defect in other locations than engine controller aPrepare with starting switch OFF and diagnose with starting switch still OFF. CE01 (female) Resistance Between (14) – (47) Max. 10 z Between (14) – ground Min. 100 kz 6 Defective engine controller Engine controller is possibly defective if no problem is found in causes 1 – 5. (Since this is an internal defect, it cannot be diagnosed.)