SEN00590-00 40 Troubleshooting Failure code [CA441] Power source voltage too low: Excessively low voltage detected 1 28 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Power source voltage too low: Excessively low voltage detected (Engine controller system) CALL E04 CA441 Failure content • Excessively low voltage has occurred in the controller power source voltage circuit Controller's action • No particular action Symptoms that appears on machine • Engine stops. • Engine is hard to start. General information • Duplication of failure code: turn ON the starting switch.
Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Loose or corroded battery terminal Battery terminal is possibly loose or corroded, so inspect it directly. 2 Defective battery voltage aPrepare with starting switch OFF and diagnose with starting switch OFF and START. Battery (1 unit) Starting switch Voltage Between (+) – (–) terminals OFF Min. 12 V START Min. 6.2 V 3 Defective fuse No. 9 If fuse is blown, it is highly possible that a defective harness ground- ing, etc. has occurred in the circuit (refer to cause 5).
4 Disconnection in wiring har- ness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between FS2 (9) – CE03 (female) (3), (4) Resis- tance Max. 10 z Wiring harness between CE03 (female) (1), (2) – ground 1 Resis- tance Max. 10 z 5 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harness between FS2 (9) – CE03 (female) (3), (4) Resis- tance Min. 100 kz 6 Harness short (Harness internal short) aPrepare with starting switch OFF and diagnose with starting switch still OFF.
Between pins CE03 (female) (3), (4) – CE03 (female) (1), (2) (Battery terminals disconnected) Resis- tance Min. 100 kz 7 Defective wiring harness connector • Since the problem is possibly at the connections between FS2 (9) – body harness – engine controller, check for a defective connection. • Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded. • Moisture in connector, entry of dirt or sand, etc., and insufficient insulation 8 Defect in other locations than engine controller aPrepare with starting switch OFF and diagnose with starting switch ON and START. CE03 (female) Starting switch Voltage Between (3), (4) – (1), (2) ON Min.
24 V START Min. 12 V 9 Defective engine controller Engine controller is possibly defective if no problem is found in causes 1 – 8. (Since this is an internal defect, it cannot be diagnosed.)