Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [CA442] POWER SOURCE VOLTAGE TOO HIGH: EXCESSIVELY HIGH VOLTAGE HAS OCCURRED IN THE CONTROLLER POWER SOURCE CIRCUIT

SEN00590-00 40 Troubleshooting Failure code [CA442] Power source voltage too high: Excessively high voltage has occurred in the controller power source circuit 1 30 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Power source voltage too high: Excessively high voltage has occurred in the controller power source circuit (Engine controller system) CALL E04 CA442 Failure content • Excessively high voltage (36 V or more) has occurred in the controller power source voltage circuit Controller's action • No particular action Symptoms that appears on machine • Engine may stop. General information • Duplication of failure code: turn ON the starting switch.

Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective battery voltage aPrepare with starting switch OFF and diagnose with starting switch still OFF. Battery Voltage Between (+) – (–) terminals Max. 32 V 2 Defective alternator aPrepare with starting switch OFF and start the engine to diag- nose. E22 (male) Engine speed Voltage Between (4) – ground Medium speed or higher 27.5 – 29.5 V 3 Defective engine controller aPrepare with starting switch OFF and diagnose with starting switch ON. CE03 (female) Voltage Between (3), (4) – (1), (2) Max. 32 V