Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [CA452] COMMON RAIL PRESSURE TOO LOW: EXCESSIVELY LOW VOLTAGE DETECTED

SEN00590-00 40 Troubleshooting Failure code [CA452] Common rail pressure sensor too low: Excessively low voltage detected 1 38 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Common rail pressure sensor too low: Excessively low voltage detected (Engine controller system) CALL E03 CA452 Failure content • Excessively low voltage is detected in the common rail pressure sensor signal circuit Controller's action • Operates with limited output. Symptoms that appears on machine • Engine does not start. • Engine speed or output is reduced. General information • The signal voltage of the common rail pressure sensor can be checked with the monitoring function. (Code:

36401 Common rail pressure sensor voltage) • Duplication of failure code: turn ON the starting switch. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective sensor power source 2 circuit If failure code [CA187] is displayed at the same time, carry out trou- bleshooting for it first. 2 Defective common rail pres- sure sensor aPrepare with starting switch OFF and diagnose with starting switch ON.

C8 Voltage Between (3) – (1) Power source 4.75 – 5.25 V Since voltage is measured with the harness connected, further diag- nose the harness and the controller if the voltage is not normal, and then make judgment after it is determined that there is no other defective cause. 3 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harness between CE01 (female) (25) – C8 (female) (2) Resis- tance Min. 100 kz 4 Harness short (Harness internal short) aPrepare with starting switch OFF and diagnose with starting switch still OFF.

Wiring harnesses between CE01 (female) (25) – C8 (female) (2) and among CE01 (female) (47) – S11 – C8 (female) (1) Resis- tance Min. 100 kz 5 Defective wiring harness connector Since the problem is possibly at the connections between common rail pressure sensor – engine harness – engine controller, check for a defective connection. • Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded. • Moisture in connector, entry of dirt or sand, etc., and insufficient insulation 6 Defective engine controller aPrepare with starting switch OFF and diagnose with starting switch ON. CE01 Voltage Between (37) – (47) Power source 4.75 – 5.25 V