Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [CA778] ABNORMAL ENGINE BKUP SPEED SENSOR: ABNORMAL BKUP SIGNAL

SEN00590-00 40 Troubleshooting Failure code [CA778] Abnormal engine Bkup speed sensor: Abnormal Bkup signal 1 50 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Abnormal engine Bkup speed sensor: Abnormal Bkup signal (Engine controller system) CALL E03 CA778 Failure content • Abnormal engine Bkup speed sensor signal has been detected. Controller's action • Continue the control using engine Ne speed sensor signal. Symptoms that appears on machine • Engine is hard to start. • Output decreases. General information • Duplication of failure code: start the engine.

Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective sensor power source 2 circuit If failure code [CA187] is displayed at the same time, carry out trou- bleshooting for it first. 2 Defective engine Bkup speed sensor aPrepare with starting switch OFF and diagnose with starting switch ON. C13 Voltage Between (1) – (2) Power source 4.75 – 5.25 V Since voltage is measured with the harness connected, further diag- nose the harness and the controller if the voltage is not normal, and then make judgment after it is determined that there is no other defective cause.

3 Damaged engine Bkup speed sensor or improper gap Since a damage of engine Bkup speed sensor or improper gap is suspected, visually check it. 4 Damaged speed detection gear Since a damage of speed detection gear is suspected, visually check it. 5 Disconnection in wiring har- ness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between CE01 (female) (26) – C13 (female) (3) Resis- tance Max. 10 z 6 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF.

Between ground and wiring harness between CE01 (female) (26) – C13 (female) (3) Resis- tance Min. 100 kz 7 Hot short in wiring harness (a contact with 5 V or 24 V cir- cuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Between ground and wiring harness between CE01 (female) (26) – C13 (female) (3) Voltage Max. 1 V