SEN00590-00 40 Troubleshooting Failure code [CA1633] Abnormal KOMNET: Abnormal communication 1 52 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Abnormal KOMNET: Abnormal communication (Engine controller system) CALL E03 CA1633 Failure content • Engine controller detected an abnormal communication in the KOMNET communication circuit between pump controller and monitor panel. Controller's action • Operate in a default mode. • When the cause of the failure has been eliminated, it returns to normal. Symptoms that appears on machine • Machine may not operate normally because the informations which are exchanged through KOM- NET communication are not trasmitted properly.
(A symptom of failure depends on the location where it occurrs.) General information • Duplication of failure code: turn ON the starting switch. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Disconnection in wiring har- ness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harnesses between S04 (female) (1), (2) – CE02 (female) (46), ST2 (female) (32), CA2 (female) (A), and CA1 (female) (A) Resis- tance Max.
1 z Wiring harnesses between S04 (female) (3), (4) – CE02 (female) (47), ST2 (female) (22), CA2 (female) (B), and CA1 (female) (B) Resis- tance Max. 1 z 2 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harnesses between S04 (female) (1), (2) – CE02 (female) (46), ST2 (female) (32), CA2 (female) (A), CA1 (female) (A) and SRV (male) (3) Resis- tance Min. 1 Mz Between ground and wiring harnesses between S04 (female) (3), (4) – CE02 (female) (47), ST2 (female) (22), CA2 (female) (B), CA1 (female) (B) and SRV (male) (10) Resis- tance Min.
1 Mz 3 Hot short of wiring harness (a contact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Between ground and wiring harnesses between S04 (female) (1), (2) – CE02 (female) (46), ST2 (female) (32), CA2 (female) (A), CA1 (female) (A) and SRV (male) (3) Voltage Max. 5.5 V Between ground and wiring harnesses between S04 (female) (3), (4) – CE02 (female) (47), ST2 (female) (22), CA2 (female) (B), CA1 (female) (B) and SRV (male) (10) Voltage Max. 5.5 V 4 Defective terminal resis- tance in CAN (Internal short circuit and dis- connection) aPrepare with starting switch OFF and diagnose with starting switch still OFF.
CA1 (male) and CA2 (male) Resistance Between (A) – (B) 120 ± 12 z 5 Defective pump controller Engine controller is possibly defective if no problem is found in causes 1 – 4. (Since this is an internal defect, it cannot be diag- nosed.)