Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [CA2311] ABNORMAL IMV SOLENOID: ABNORMAL RESISTANCE

SEN00590-00 40 Troubleshooting Failure code [CA2311] Abnormal IMV solenoid: Abnormal resistance 1 62 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Abnormal IMV solenoid: Abnormal resistance (Engine controller system) CALL E03 CA2311 Failure content • Resistance value of supply pump actuator circuit is abnormaly high or low. Controller's action • No particular action Symptoms that appears on machine • Engine output decreases. General information • Duplication of failure code: start the engine.

Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective related circuits Check the failure codes that are displayed at the same time. If any other codes are displayed, carry out troubleshooting for those codes. 2 Defective supply pump actu- ator aPrepare with starting switch OFF and diagnose with starting switch still OFF. C17 (male) Resistance Between (1) – (2) Max. 5 z Between (1) – chassis ground Min. 100 kz 3 Disconnection in wiring har- ness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF.

Wiring harness between CE01 (female) (2) – C17 (female) (1) Resis- tance Max. 5 z Wiring harness between CE01 (female) (32) – C17 (female) (2) Resis- tance Max. 5 z 4 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harness between CE01 (female) (2) – C17 (female) (1) Resis- tance Min. 100 kz 5 Defective wiring harness connector Since the connections among inlet metering valve – engine harness – engine controller are suspected to be defective, visually check for a defective connection.

• Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded. • Moisture in connector, entry of dirt or sand, etc., and insufficient insulation 6 Defect in other locations than engine controller aPrepare with starting switch OFF and diagnose with starting switch still OFF. CE01 (female) Resistance Between (2) – (32) Max. 5 z Between (2) – chassis ground Min. 100 kz 7 Defective engine controller Engine controller is possibly defective if no problem is found in causes 1 – 6. (Since this is an internal defect, it cannot be diagnosed.)