SEN00590-00 40 Troubleshooting Failure code [CA2555] Air intake heater relay disconnection: Disconnection 1 64 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Air intake heater relay disconnection: Disconnection (Engine controller system) E01 CA2555 Failure content • Disconnection is detected in the drive circuit of air intake heater relay. Controller's action • No particular action Symptoms that appears on machine • Air intake heater does not operate (Startability deteriorates in a low temperature and white smoke is exhausted.) General information • Duplication of failure code: Turn the starting switch ON with coolant temperature below -4°C.
Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective preheat relay (internal disconnection) aPrepare with starting switch OFF and diagnose with starting switch still OFF (diagnose by itself). RHR (male) Resistance Between (1) – (2) 300 – 600 z aPrepare with starting switch OFF and diagnose with starting switch ON (diagnose by replacing with other relay) Replace preheat relay (RHR) with other relay and carry out the pro- cedure to duplicate the failure code. If failure code changes from flashing to steady ON, the relay is defective.
2 Disconnection in wiring har- ness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between CE02 (female) (40) – RHR (female) (1) Resis- tance Max. 10 z Wiring harness between CE02 (female) (42) – RHR (female) (2) Resis- tance Max. 10 z 3 Harness short (Harness internal short) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between CE02 (female) (40) – all pins of CE02 (female) (with RHR also disconnected) Resis- tance Min.
100 kz 4 Defective wiring harness connector The connections among preheat relay – body harness – engine con- troller are suspected to be defective. Visually check them. • Connector is loose, lock is broken, seal is broken • Pin is corroded, bent, broken, pushed in, expanded. • Moisture in connector, entry of dirt or sand, etc., and insufficient insulation 5 Defect in other locations than engine controller aPrepare with starting switch OFF and diagnose with starting switch still OFF. CE02 (female) Resistance Between (40) – (42) 300 – 600 z 6 Defective engine controller Engine controller is possibly defective if no problem is found in causes 1 – 5.
(Since this is an internal defect, it cannot be diagnosed.)