Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [D110KA] BATTERY RELAY: SHORT CIRCUIT

SEN00591-00 40 Troubleshooting Troubleshooting by failure code (Display of code), Part 3 1 Failure code [D110KA] Battery relay: Short circuit 1 4 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Battery relay: Short circuit (Steering and transmission controller system) — D110KA Failure content • Abnormal current flowed to battery relay circuit when outputting it. Controller's action • Stops output to battery relay circuit. Symptoms that appears on machine • Problem may occur in data writing to ROM (nonvolatile memory) of each controller. General information • Output status (voltage) to battery relay can be checked in monitoring mode. (Code 60600:

Battery relay drive voltage) • Method of reproducing failure code: Switch starting switch from ON o OFF. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective battery relay (internal disconnection) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Battery relay Continuity Between SW terminal – SWG terminal Continue Between SW terminal – ground Min. 1 Mz 2 Disconnection in wiring harness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF.

Wiring harness between ST3 (female) (4) – battery relay SW terminal and S13 (female) (10) – RSD (female) (1) with ground Resis- tance Min. 1 Mz 3 Defective diode (Internal short-circuiting) See the section of testing procedure of diode (Testing and adjust- ing). 4 Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch ON. ST3 (female) Starting switch Voltage Between (4) – chassis ground ON 20 – 30 V