SEN00591-00 40 Troubleshooting Failure code [D110KB] Battery relay: Disconnection 1 6 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Battery relay: Disconnection (Steering and transmission controller system) — D110KB Failure content • Current does not flow when outputting it to battery relay circuit. Controller's action • Stops output to battery relay circuit. Symptoms that appears on machine • Problem may occur in data writing to ROM (nonvolatile memory) of each controller. General information • Output status (voltage) to battery relay can be checked in monitoring mode. (Code 60600: Battery relay drive voltage) • Method of reproducing failure code:
Switch starting switch from ON o OFF. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective battery relay (internal disconnection) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Battery relay Continuity Between SW terminal – SWG terminal Continue 2 Disconnection in wiring harness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harnesses between ST3 (female) (4) – battery relay SW terminal Resis- tance Max. 1 z Wiring harnesses between SWG terminal – GND03 Resis- tance Max.
1 z 3 Hot short of wiring harness (Contact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between ST3 (female) (4) – battery relay SW terminal and S13 (female) (10) – RSD (female) (1) with ground Voltage Max. 1 V 4 Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch still OFF. ST3 (female) Continuity Between (4) – chassis ground Continue