Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [D130KB] NEUTRAL SAFELY RELAY: SHORT CIRCUIT

SEN00591-00 40 Troubleshooting Failure code [D130KB] Neutral safety relay: Short circuit 1 10 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Neutral safety relay: Short circuit (Steering and transmission controller system) E02 D130KB Failure content • Abnormal current flowed in neutral safety relay circuit at the time of ground output. Controller's action • Flashes warning lamp and turns on alarm buzzer. • Stops ground output to neutral safety relay circuit. Symptoms that appears on machine • Engine does not start. General information • Output status (voltage) to neutral safety relay can be checked in monitoring mode. (Code 50900:

Neutral safety relay drive voltage) • Method of reproducing failure code: Turn starting switch ON + Shift parking brake lever (to lock position) aThis failure code detects abnormality in primary side (coil side) of neutral safety relay, but not in sec- ondary side (contact side). Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective neutral safety relay (internal disconnection) aPrepare with starting switch OFF and diagnose with starting switch still OFF.

NSF (male) Resistance Between (1) – (2) 200 – 400 z 2 Hot short of wiring harness (Contact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Wiring harness between ST2 (female) (8) – NSF (female) (2) with ground. Voltage Max. 1 V 3 Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch ON. ST2 Parking lever Voltage Between (8) – chassis ground Free position 20 – 30 V Lock position Max. 1 V