SEN00591-00 40 Troubleshooting Failure code [D161KA] Back-up alarm relay: Disconnection 1 12 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Back-up alarm relay: Disconnection (Steering and transmission controller system) E01 D161KA Failure content • 24 V is not generated at neutral safety relay circuit when ground is shut off. Controller's action • Stops ground output to back-up alarm relay circuit. Symptoms that appears on machine • Back-up alarm does not turn on. • Back-up alarm turns on, regardless of positions of steering and forward-reverse lever and gear shift lever. General information • Output status (voltage) to back-up alarm relay can be checked in monitoring mode.
(Code 70400: Back-up alarm relay drive voltage) • Method of reproducing failure code: Turn starting switch ON + Shift steering and forward-reverse lever and gear shift lever to neutral aThis failure code detects abnormality in primary side (coil side) of back-up alarm relay, but not in sec- ondary side (contact side). Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective fuse FS2-9 If fuse is blown, circuit probably has short circuiting with ground. 2 Defective back-up alarm relay (internal disconnection) aPrepare with starting switch OFF and diagnose with starting switch still OFF.
BKA (male) Resistance Between (1) – (2) 200 – 400 z 3 Disconnection in wiring harness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between ST2 (female) (18) – BKA (female) (2) Resis- tance Max. 1 z Wiring harnesses between BKA (female) (1) – FS2-6 outlet Resis- tance Max. 1 z 4 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between ST2 (female) (18) – BKA (female) (2) with ground. Resis- tance Min. 1 Mz Between wiring harnesses of BKA (female) (1) – FS2-6 outlet and ground Resis- tance Min.
1 Mz 5 Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch ON. ST2 PCCS lever Voltage Between (18) – chassis ground Neutral position 20 – 30 V Reverse position Max. 1 V