SEN00591-00 40 Troubleshooting Failure code [D161KB] Back-up alarm relay: Short circuit 1 14 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Back-up alarm relay: Short circuit (Steering and transmission controller system) E01 D161KB Failure content • Abnormal current flowed in back-up alarm relay circuit at the time of ground output. Controller's action • Stops ground output to back-up alarm relay circuit. Symptoms that appears on machine • Back-up alarm does not turn on. General information • Output status (voltage) to back-up alarm relay can be checked in monitoring mode. (Code 70400: Back-up alarm relay drive voltage) • Method of reproducing failure code:
Turn starting switch ON + Shift steering and forward-reverse lever and gear shift lever (to reverse) aThis failure code detects abnormality in primary side (coil side) of back-up alarm relay, but not in sec- ondary side (contact side). Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective back-up alarm relay (internal disconnection) aPrepare with starting switch OFF and diagnose with starting switch still OFF. BKA (male) Resistance Between (1) – (2) 200 – 400 z 2 Hot short of wiring harness (Contact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON.
Wiring harness between ST2 (female) (18) – BKA (female) (2) with ground. Voltage Max. 1 V 3 Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch ON. ST2 Parking lever Voltage Between (18) – chassis ground Neutral position 20 – 30 V Reverse position Max. 1 V