Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [DAQ6KK] [DB36KK] STEERING AND TRANSMISSION CONTROLLER SENSOR 24V POWER SOURCE: POWER SOURCE VOLTAGE DROP AND INPUT

SEN00591-00 40 Troubleshooting Failure code [DAQ6KK] [DB36KK] Steering and transmission controller sensor 24 V power source: Power source voltage drop and input 1 26 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Steering and transmission controller sensor 24 V power source: Power source voltage drop and input (Steering and transmission controller system) CALL E03 DAQ6KK DB36KK Failure content • Voltage of 24 V power source circuit of steering and transmission controller sensor is less than 12 V or more than 30 V. • Abnormal current flowed in 24 V power source circuit of steering and transmission controller sensor.

Controller's action • Flashes warning lamp and turns on alarm buzzer. • Limits operation of engine and transmission. • Stops output to 24 V power source circuit if abnormal voltage flows. Symptoms that appears on machine • System may not operate normally. • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1. General information • Both of DAQ6KK and DB36KK are displayed. • Duplication of failure code: turn ON the starting switch.

Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective pitch angle sensor (internal short circuit) If right-hand connector is disconnected and service code lights up (to indicate returning to normal), the cause is an internal trouble, aTurn starting switch OFF, disconnect connector, turn the switch ON and carry out troubleshooting. PT1 connector 2 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between ST1 (female) (16) – PT1 (female) (C) with ground. Resis- tance Min.

1 Mz 3 Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch still OFF. ST1 Voltage Between (16) – (21) 20 – 30 V