SEN00591-00 40 Troubleshooting Failure code [DD12KA] Shift up switch: Disconnection 1 34 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Shift up switch: Disconnection (Steering and transmission controller system) E02 DD12KA Failure content • Signals of two systems of shift up switch circuit were turned OFF (OPEN) at the same time. Controller's action • Flashes warning lamp and turns on alarm buzzer. • Recognizes that switch is not pressed. Symptoms that appears on machine • Cannot shift up. • The auto shift down function does not work. General information • Of signals of two systems of switch, NO is for operation detection and NC is for error detection.
• Input status (ON / OFF) from shift up switch can be checked in monitoring mode. (Code 40905: Transmission-related controller input signal 1) • Method of reproducing failure code: Turn starting switch ON + Operate shift up switch Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective shift up switch (internal disconnection) aPrepare with starting switch OFF and diagnose with starting switch still OFF. SFTU (male) Shift up switch OFF (Release) ON (Press) Resistance between (2) – (3) Max. 1 z Min. 1 Mz Resistance between (2) – (1) Min. 1 Mz Max.
1 z 2 Disconnection in wiring har- ness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between ST1 (female) (12) – SFTU (female) (3) Resis- tance Max. 1 z Wiring harness between ST3 (female) (9) – SFTU (female) (1) Resis- tance Max. 1 z Wiring harness between ST1 (female) (4) – SFTU (female) (2) Resis- tance Max. 1 z 3 Hot short of wiring harness (Contact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Wiring harness between ST1 (female) (12) – SFTU (female) (3) with ground Voltage Max.
1 V Wiring harness between ST3 (female) (9) – SFTU (female) (1) with ground Voltage Max. 1 V 4 Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch ON. ST1, ST3 Shift up switch OFF (Release) ON (Press) Voltage between ST1 (12) – ST1 (4) Max. 1 V 5 – 11 V Voltage between ST3 (9) – ST1 (4) 5 – 11 V Max. 1 V