SEN00591-00 40 Troubleshooting Failure code [DD12KB] Shift up switch: Short circuit 1 36 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Shift up switch: Short circuit (Steering and transmission controller system) E02 DD12KB Failure content • Signals of two systems of shift up switch circuit were turned ON (CLOSE) at the same time. Controller's action • Flashes warning lamp and turns on alarm buzzer. • Recognizes that switch is not pressed. Symptoms that appears on machine • Cannot shift up. • The auto shift down function does not work. General information • Of signals of two systems of switch, NO is for operation detection and NC is for error detection.
• Input status (ON / OFF) from shift up switch can be checked in monitoring mode. (Code 40905: Transmission-related controller input signal 1) • Method of reproducing failure code: Turn starting switch ON + Operate shift up switch Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective shift up switch (internal short circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. SFTU (male) Shift up switch OFF (Release) ON (Press) Resistance between (2) – (3) Max. 1 z Min. 1 Mz Resistance between (2) – (1) Min. 1 Mz Max.
1 z 2 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between ST1 (female) (12) – SFTU (female) (3) with ground Resis- tance Min. 1 Mz Wiring harness between ST3 (female) (9) – SFTU (female) (1) with ground Resis- tance Min. 1 Mz 3 Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch ON. ST1, ST3 Shift up switch OFF (Release) ON (Press) Voltage between ST1 (12) – ST1 (4) Max. 1 V 5 – 11 V Voltage between ST3 (9) – ST1 (4) 5 – 11 V Max. 1 V