SEN00591-00 40 Troubleshooting Failure code [DDN7KB] Pitch control switch: Short circuit 1 48 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Pitch control switch: Short circuit (Steering and transmission controller system) E02 DDN7KB Failure content • Signals of two systems of pitch control switch circuit were turned ON (CLOSE) at the same time. Controller's action • Flashes warning lamp and turns on alarm buzzer. • Recognizes that switch is not pressed. Symptoms that appears on machine • Pitch control is not available. General information • Of signals of two systems of switch, NO is for operation detection and NC is for error detection.
• Input status (ON / OFF) from pitch control switch can be checked in monitoring mode. (Code 70300: Work equipment related controller input signal) • Duplication of failure code: Turn starting switch ON and operate pitch control switch. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective pitch control switch (internal short circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. P0A (male), P0B (female) Pitch control switch OFF (Release) ON (Press) Resistance between (2) – (3) Max. 1 z Min. 1 Mz Resistance between (2) – (1) Min. 1 Mz Max.
1 z 2 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between ST3 (female) (10) – P0A (female) (3) with ground Resis- tance Min. 1 Mz Wiring harness between ST3 (female) (20) – P0A (female) (1) – P0B (male) (1) with ground Resis- tance Min. 1 Mz Wiring harness between P0A (female) (2) – P0B (male) (3) with ground Resis- tance Min. 1 Mz 3 Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch ON. ST1, ST3 Pitch control switch OFF (Release) ON (Press) Voltage between ST3 (10) – ST1 (4) Max.
1 V 5 – 11 V Voltage between ST3 (20) – ST1 (4) 5 – 11 V Max. 1 V