Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [DGS1KX] HYDRAULIC OIL TEMPERATURE SENSOR: INPUT SIGNAL IS OUT OF NORMAL RANGE

SEN00591-00 40 Troubleshooting Failure code [DGS1KX] Hydraulic oil temperature sensor: Input signal is out of normal range 1 52 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Hydraulic oil temperature sensor: Input signal is out of normal range (Steering and transmission controller system) — DGS1KX Failure content • Hydraulic oil temperature sensor signal is out of normal range. Controller's action • Only memorizes the trouble. There is no need to raise an alarm in particular. Symptoms that appears on machine • Hydraulic oil temperature on monitor panel is not displayed normally. • Fan speed is limited to half.

General information • Hydraulic oil temperature status (temperature) can be checked in monitoring mode. (Code 04401: Hydraulic oil temperature) • Method of reproducing failure code: Turn starting switch ON or start engine. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective hydraulic oil tem- perature sensor (Internal disconnection and short circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. SDS (male) Resistance Between (1) – (2) 3.5 k – 90 kz (10 – 100°C) Between (1), (2) – chassis ground Min.

1 Mz 2 Disconnection in wiring harness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between ST1 (female) (9) – SDS (female) (1) Resis- tance Max. 1 z Wiring harness between ST1 (female) (21) – SDS (female) (2) Resis- tance Max. 1 z 3 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harness between ST1 (female) (9) – SDS (female) (1) Resis- tance Min.

1 Mz 4 Hot short of wiring harness (Contact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Between ground and wiring harness between ST1 (female) (9) – SDS (female) (1) Voltage Max. 1 V 5 Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch still OFF. ST1 (female) Resistance Between (9) – (21) 3.5 k – 90 kz (10 – 100°C) Between (9) – chassis ground Min. 1 Mz