Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — COOLING FAN PUMP

10 Structure, function and maintenance standard SEN00281-01 Function Operation q The servo valve controls the current input to the EPC valve and the swash plate angle of the pump so that they will be related as shown in the diagram. q The output pressure of EPC valve is applied to piston chamber (C) to push piston (6). Piston (6) pushes spool (5) until it is balanced with the spring. q Then, land (PE) of the servo piston pressure passage is connected to the pump discharge passages by the notch of spool (5) and the dis- charge pressure is led to the servo piston. q The servo piston is raised by the rocker com. Then, the position feedback is applied and the lever moves to compress the spring.

q If spool (5) is pushed back, the pump dis- charge circuit and the servo piston circuit are shut off. The pressure in the servo piston chamber lowers and the rocker cam returns toward the maximum swash plate angle. q These processes are repeated until the swash plate is fixed to a position where the EPC out- put is balanced with the spring force. q The relationship between the input current (i) to the EPC valve and output pressure (F) of EPC valve is as follows. q Accordingly, as the EPC output pressure is heightened, the swash plate angle is decreased. As the EPC output pressure is low- ered, the swash plate angle is increased. D65EX, PX, WX-15E0 11