Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [DWN2KY] HSS EPC SOLENOID LEFT: SHORT CIRCUIT TO POWER SOURCE LINE

40 Troubleshooting SEN00592-00 Failure code [DWN2KY] HSS EPC solenoid left: Short circuit to power source line 1 Circuit diagram related to HSS EPC solenoid left D65EX, PX, WX-15E0 19 Action code Failure code DWN2KY Sympto of failur m HSS EPC solenoid left: Short circuit to power source line e (Steering and transmission controller system) CALL E04 Failure conte nt • Current flows constantly to HSS EPC solenoid left circuit. Controller' action • Flashes warning lamp and turns on alarm buzzer. s • Stops outputting to HSS EPC solenoid left circuit. • Limits operation of engine and transmission. Symptoms th appears on machin at • Continues to turn to the left.

• Once machine is stopped, engine speed is limited to medium (half). e • Can not travel once machine is stopped. General information • Output state (current) to HSS EPS solenoid left can be checked in monitoring mode. (Code 50602: Left HSS solenoid output current value) • Duplication of failure code: Turn starting switch ON and operate PCCS lever (for steering to left).

Possible causes and t standard valu when norm Cause Defective HSS EPC soleno left 1 (Internal disconnection and short circuit) he Hot short of wiring harness 2 es (a contact with 24 V circuit) al Defective steering and 3 transmission controller Standard value when normal and remarks for troubleshooting Defective HSS EPC soleno left (Internal disconnection and short circuit) aPrepare with starting switch OFF and diagnose with starting id switch still OFF. HSA (male) Resistance Between (1) – (2) 5 – 15 z Resistance 5 – 15 z Hot short of wiring harness (a contact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON.

Between ground and wiring harness between Voltage Max. 1 V ST3 (female) (25) – HSA (female) (1) Voltag e Max. 1 V Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch ON. ST3 PCCS lever Voltage Left 5 – 15 V Between (25) – (3) N Max. 1 V PCCS lever Voltage Left 5 – 15 V N Max. 1 V