Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — BEFORE TROUBLESHOOTING OF ELECTRICAL SYSTEM

40 Troubleshooting SEN00593-00 Troubleshooting of electrical system (E-mode) 1 Before troubleshooting of electrical system 1 Wiring table for fuse box a This wiring diagram shows apparatuses to which electric power is supplied through the fuse box. (A switching electric power supply supplies power with the starting switch ON. Constant electric power sup- ply supplies power with starting switch either ON or OFF.) a When you do troubleshooting related to the electrical systems, you should first check the fuse or the fus- ible link to see whether the power is supplied normally or not. Fuse box A [FS1] Fuse box B [FS2] Cab fuse box C D65EX, PX, WX-15E0 3 Fuse No.

Electric supply source Fuse capacity (A) Destinations of electric power distribution 1 Switched electric power supply 20 Standby electric power supply 2 20 Horn, electrical intake air heater, air suspension seat 3 20 Front lamp, rear lamp 4 20 Steering and transmission controller (electric power supply to solenoid) 5 5 Engine controller (ACC signal) Fuse No.

Electric supply source Fuse capacity (A) Destinations of electric power distribution 1 Switched electric power supply 5 Backup alarm 2 Constant power source 15 Steering and transmission controller (main electric power supply), Radio 3 30 Electric power supply of machine (with 20A circuit breaker in the circuit) 4 30 Engine controller (main electric power supply) 5 Switched electric power supply 30 Air conditioner (with 20A circuit breaker in the circuit) Fuse No.

Electric supply source Fuse capacity (A) Destinations of electric power distribution 1 Switched electric power supply 10 Accessory electric power supply (12 V electric power supply) 2 20 Radio, room lamp, cigarette lighter, additional light 3 20 Glass with heating wire 4 10 Rear wiper 5 10 Front wiper 6 10 Left and right door wipers