Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — COOLING FAN MOTOR

SEN00281-01 10 Structure, function and maintenance standard 3. Operation of reversible valve (1) When the ON-OFF solenoid for the revers- ible valve is demagnetized (2) When ON-OFF solenoid for reversible valve is energized q If ON-OFF solenoid (1) for the reversible valve is “demagnetized“, the pressurized oil from the pump is blocked by ON-OFF selector valve (2), and port (C) opens for the tank circuit. q If ON-OFF solenoid (1) for reversible valve is “energized“, ON-OFF selector valve (2) changes to let the pressurized oil from the pump flow through port (C) into spool chamber (D).

q Accordingly, reversible valve spool (3) is pushed by reversible valve spring (4) to the right to open motor port (MA) and then the pressurized oil flows in to revolve the motor forward (clock- wise). q The pressurized oil in chamber (D) pushes reversible valve spool (3) to the left against reversible valve spring (4). As a result, motor port (MB) opens and pressurized oil flows in to revolve the motor in reverse (counterclock- wise). 16 D65EX, PX, WX-15E0