Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — E-2 THE PREHEATER DOES NOT OPERATE

SEN00593-00 40 Troubleshooting E-2 The preheater does not operate. 1 10 D65EX, PX, WX-15E0 Symptom of failure • The preheater does not operate. General information aThis troubleshooting describes the procedures to be followed when the automatic and manual pre- heating does not function to heat the electrical intake air heater mounting section. (When only the preheating lamp does not light up, carry out the troubleshooting of “E-7 The preheat- ing pilot lamp does not light up”) • For preheating, both the “Automatic preheating function” and “Manual preheating function” are avail- able. When either function is performed, the preheating lamp comes on.

• If “the monitor panel does not light up ”or “the battery relay does not make operating sound” when turning the starting switch ON, the main electric power supply system is supposed to be defective. So, check the main electric power supply system. • Before starting the troubleshooting, validate that the related failure code is not displayed.

(If the failure code [CA153], [CA154], [CA2555] or [CA2556] is displayed, firstly conduct this trouble- shooting.) Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective starting switch (internal disconnection) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Starting switch Switch position Resistance Between 250 (B) – 255 (R1) OFF Min. 1 Mz HEAT (R1) Max. 1 z 2 Defective fuse (FL2, FS1, FS2) If fuse is burnt, it is highly possible that a defective harness ground- ing, etc. has occurred in the circuit.

3 Defective preheater relay (internal disconnection) aPrepare with starting switch OFF and diagnose with starting switch ON. If preheating starts normally at the intake air temperature below –5°C after the preheater relay RHR is replaced with another one, the preheater relay RHR is defective. 4 Defective heater relay (internal defect) aPrepare with the starting switch OFF and diagnose with the start- ing switch HEAT. Heater relay Voltage Electric power supply: between terminal HT/B and ground 20 – 30 V Signal: between terminal HT/C and ground 20 – 30 V When the both voltages of electric power supply and signal are nor- mal and no operating sound is heard, the heater relay is defective.

5 Defective diode (internal short circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Diagnose diode GND (male) • See the “Inspection procedure of diode” in the “Testing and adjusting” section. 6 Defective electrical intake air heater (internal defect) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Electrical intake air heater Continuity Between terminals Continue