SEN00593-00 40 Troubleshooting E-7 While the preheater is operating, the preheating pilot lamp does not light up. 1 22 D65EX, PX, WX-15E0 Symptom of failure While the preheater is operating, the preheating pilot lamp does not light up. General information aThis troubleshooting describes the procedures to be followed when the preheating lamp doe not light up. (When the electrical intake air heater mounting section is not heated, carry out the troubleshoot- ing of “E-2 The preheater does not operate.”) • For preheating, both the “Automatic preheating function” and “Manual preheating function” are avail- able. When either function is performed, the preheating lamp comes on.
Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Disconnection in wiring har- ness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between S03 (female) (9) – RHR (female) (3) Resis- tance Max. 1 z 2 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harness between S03 (female) (9) – RHR (female) (3) Resis- tance Min.
1 Mz 3 Defective monitor panel aPrepare with starting switch OFF and diagnose with starting switch ON. S03 Starting switch Voltage Between (9) – ground ON Min. 1 V HEAT Min. 7 V