Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — E-9 THE POWER TRAIN OIL TEMPERATURE GAUGE DOES NOT INDICATE CORRECTLY.

SEN00593-00 40 Troubleshooting E-9 The power train oil temperature gauge does not indicate correctly. 1 26 D65EX, PX, WX-15E0 Symptom of failure (1)Although the power train oil temperature is rising normally, the indication of the power train oil tem- perature stays in white range (a). (2)Although the power train oil temperature is stabilized normally, the indication of the power train oil temperature rises to red range (c). General information • The input state (temperature) from the power train oil temperature sensor can be checked in the monitoring mode. (Code 30100:

Power train oil temperature) • If an abnormality takes place in the power train oil temperature sensor circuit, the failure code [DGT1KA] or [DGT1KX] may be displayed. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective power train oil tem- perature sensor (internal disconnection or short circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. 453 (male) Torque converter oil temperature Resistance Between (1) – (2) 10 – 100°C 3.5 – 90 kz Between (1) – chassis ground Min.

1 Mz 2 Disconnection in wiring har- ness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between S04 (female) (12) – 453 (female) (1) Resis- tance Max. 1 z Wiring harness between 453 (female) (2) – S03 (female) (3) Resis- tance Max. 1 z 3 Defective grounding of wiring harness (a contact with GND circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harness between S04 (female) (12) – 453 (female) (1) Resis- tance Min.

1 Mz 4 Hot short of wiring harness (a contact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Between ground and wiring harness between S04 (female) (12) – 453 (female) (1) Voltage Max. 1 V Between ground and wiring harness between 453 (female) (2) – S03 (female) (3) Voltage Max. 1 V 5 Defective monitor panel aPrepare with starting switch OFF and diagnose with starting switch still OFF. S04 (female) Power train oil temperature Resistance Between (12) – ground 10 – 100°C 3.5 – 90 kz