Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — E-20 THE PRESET MODE DOES NOT OPERATE OR CANNOT BE RESET.

SEN00593-00 40 Troubleshooting E-20 The preset mode does not operate or cannot be reset. 1 42 D65EX, PX, WX-15E0 Symptom of failure • The preset mode does not operate or cannot be reset. General information Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective manual mode switch (Internal disconnec- tion) aPrepare with starting switch OFF and diagnose with starting switch still OFF. MAM (male) Preset mode switch Resistance Between (2) – (3) OFF(0) Min. 1 Mz ON(1) Max.

1 z 2 Defective harness grounding (Disconnection in wiring or defective contact) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between ST2 (female) (10) – MAM (female) (2) Resis- tance Max. 1 z Wiring harness between MAM (female) (3) – ground Resis- tance Max. 1 z 3 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harness between ST2 (female) (10) – MAM (female) (2) Resis- tance Max. 1 Mz 4 Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch ON.

ST2 Preset mode switch Voltage Between (10) – ground OFF(0) 5 – 11 V ON(1) Max. 1 V 5 Limitation of function by controller When Causes 1 to 4 are not applicable, steering and transmission controller may be limiting function because of another reason.