SEN00593-00 40 Troubleshooting E-21 The monitor panel cannot be set in the service mode or cannot be set out of the service mode. 1 44 D65EX, PX, WX-15E0 Symptom of failure • The monitor panel cannot be set in the service mode or cannot be set out of the service mode. General information Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective buzzer cancel switch system Since the buzzer cancel switch system is supposed to be out of order, carry out the troubleshooting of ”E-17 The buzzer cancel switch does not work”.
2 Defective information switch system Since the information switch system is supposed to be out of order, carry out the troubleshooting of “E-18 The information switch does not work”. 3 Defective fuse FS2(7) When the fuse FS2 (7) is cut off, a ground fault may have possibly occurred in the circuit. 4 Defective service switch (Internal short circuit or dis- connection) aPrepare with starting switch OFF and diagnose with starting switch still OFF. S24 Service switch Resistance Between (1) – (2) Between (5) – (4) OFF Min. 1 Mz ON Max.
1 z 5 Disconnection in wiring harness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between FS2 (7) outlet – S24 (1) Resis- tance Max. 1 z Wiring harness between S24 (4) – ground Resis- tance Max. 1 z Wiring harness between S03 (female) (16) – S24 (2) Resis- tance Max. 1 z Wiring harness between ST1 (female) (6) – S24 (5) Resis- tance Max. 1 z 6 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harness among FS2 (7) – S24 (1) – S03 (female) (5) (6) Resis- tance Max.
1 Mz Between ground and wiring harness between S24 (5) – ST1 (female) (6) Resis- tance Max. 1 Mz 7 Hot short of wiring harness (a contact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Between ground and wiring harness between S24 (2) – S03 (female) (16) Voltage Max. 1 V 8 Defective monitor panel aPrepare with starting switch OFF and diagnose with starting switch ON. S03 Service switch Voltage Between (16) – ground OFF Max. 1 V ON 20 – 30 V 9 Defective steering and transmission controller aPrepare with starting switch OFF and diagnose with starting switch ON. ST1 Service switch Voltage Between (6) – ground OFF 5 – 11 V ON Max. 1 V